CMA Dishmachines L-1X Dishwasher User Manual


 
1.2. L-1X and L-1X16 Operational Cycle
The L-1X and L-1X16 Operational Cycle has a total cycle time of 2 minutes (120
seconds). The Timing Diagram and the steps listed below detail the individual functions
that are executed during each Operational Cycle.
Seconds: 0 10 20 30 40 50 60 70 80 90 100 110
120
W
ASH
RINSE
DRAIN
Instant
Start Relay
Cam 1
Start/Stop
Cam 2
Detergent
Drain/Rack
Counter
Cam 3
Cam 4
Flush/Fill
Cam 5
Sanitize
r
Cam 6
Rinse
Pump Motor
Cam 7
Heater*
Cam 8
*Heater is optional
1. With the machine powered up, toggling the START switch begins a cycle.
a) Toggling the START switch energizes both the cam timer motor and the instant
start relay. The instant start relay latches ON the power to the cam timer motor so
that the START switch can be released a moment after it has been toggled without
the cam timer motor losing power.
b) After about 2 seconds, Cam 1—the Start cam—latches ON the power to the cam
timer motor and drops out the instant start relay. The cam timer motor continues
to run for a total of 2 minutes, at which time it switches OFF—resetting the cam
timer—and waits for the next start command.
2. Cam switch 7 controls the pump motor. The pump motor comes ON at the beginning
of the operational cycle and continues to run until the end of the drain function
(controlled by cam switch 3), at which time it turns off for about eight seconds
MODEL L-1X & L-1X16 INSTALLATION & OPERATION MANUAL Rev. 1.14 Page
3