Connection to the electricity supply should be made via a properly earthed, readily accessible wall
socket which is adjacent to, and not more than 1.25m away from the appliance and capable of electri-
cal isolation.
The mains lead should be routed such that it cannot touch hot parts of the appliance i.e. the back
panel above a height of 350mm from the bottom of the oven recess. If the oven is to be wired into a
connector unit, this may be positioned behind the oven providing the following requirements are
met:
i) The connector unit must not project more than 25mm from the wall.
ii) The top of the connector unit must not be more than 350mm above the base of the oven recess.
IF THE FITTED PLUG IS REMOVED
The flexible mains lead must be correctly connected as below to a three pin plug of not less than 13
amp capacity. If a B.S. 1363 fused plug is used, it must be fitted with a 3 amp fuse which is approved
to B.S. 1362.
IMPORTANT: The wires in the mains lead fitted to
this appliance are coloured in
accordance with the following code:
GREEN AND YELLOW – EARTH
BLUE – NEUTRAL
BROWN – LIVE
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:– The wire which is coloured green and yellow must be connected to the terminal
in the plug which is marked with the letter E or by the earth symbol or coloured green or green
and yellow. The wire which is coloured blue must be connected to the terminal which is marked with
the N or coloured black. The wire which is coloured brown must be connected to the terminal which
is marked with the letter L or coloured red. When wiring the plug, ensure that all strands of wire are
securely retained in each terminal. Do not forget to tighten the mains lead clamp on the plug. As the
appliance must be earthed, do not use 2-pin sockets outlets, if you are in doubt, consult a qualified
electrician.
Should the mains lead ever require replacement, it is essential that this operation be carried out by a
qualified electrician and should only be replaced with a flexible cord of the same size i.e. 0.75mm
2
cross sectional area and temperature rating of 85
0
C e.g. heat resisting PVC.
IF A MOULDED PLUG IS FITTED
In the event of replacing a fuse in the plug supplied a 3 amp ASTA approved fuse to BS1362 must be
fitted.
NOTE: The fuse cover must be refitted when changing the fuse. In the event of losing the fuse cover
the plug must not be used until a replacement fuse cover has been obtained and fitted. A new fuse
cover can be obtained from your local electrical retailer. The colour of the correct replacement fuse
cover is that of the coloured marks or inserts in the base of the plug.
ELECTRICAL CONNECTION
WARNING – THIS APPLIANCE MUST BE EARTHED.
CONNECT TO A 230-240V A.C. SUPPLY ONLY.
Green &
Yellow to
Earth
Brown to
Live
Blue to
Neutral
Cord Clamp
3 Amp
Fuse
NOTE: The removed plug cannot be used for any other appliance and should
therefore be properly disposed of and not left where children might find it and plug it into
a supply socket – with the obvious consequent danger.
31