Creda S840G Cooktop User Manual


 
12
Characteristic of the burners and nozzles
Table 1
Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin. Ridot. (mm) (mm) *** ** (mm)
Fast (R) 100 3,00 0,70 41 86 218 214 116 286
Semi Fast (S) 75 1,90 0,40 30 70 138 136 106 181
Auxiliary (A) 55 1,00 0,40 30 50 73 71 79 95
Triple Crown (TC) 100 2,50 0,80 48 83 182 179 124 238
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar-dry gas
** Propane P.C.S. = 50.37 MJ/kg.
*** Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
(1) re. Models with the security device (Ref. F).
S S
R A
SS
RA
SSAAA
TCTC RRR
S 830 G S 840 G