Creda S912E Cooktop User Manual


 
6
Electrical connection
This appliance conforms with the following European
Community Directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89 (Electromagnetic
compatibility) and subsequent amendments;
- 93/68/EEC of 22/07/93 and subsequent amendments;
Warning: If the hob is fitted above a built-in oven, the hob
and the oven must be connected to the mains separately for
safety reasons and to simplify operations when it is necessary
to pull the oven out for some reason.
The electrical safety of this appliance can only be
guaranteed if the latter is correctly and efficiently
earthed, in compliance with regulations on electrical
safety. Always ensure that this vital safety measure has
been taken. If you have any doubts, call in a qualified
technician to check the electrical system thoroughly.
The manufacturer denies all responsibility for dam-
age resulting from a system which has not been
earthed correctly.
Before powering the appliance, check whether the
technical characteristics featured on the appliance data
plate correspond with those of the mains electrical sys-
tem.
Check that the current load of the mains supply and
of the power sockets is suitable for the maximum power
of the appliance, indicated on the appliance data plate.
If in doubt, contact a qualified professional.
Disconnect the appliance from the electricity supply
before all operations.
You may connect your hob to the electrical system in two
different ways:
by means of a junction box: if the appliance is
connected permanently to the mains, an omnipolar
circuit breaker, accessible if necessary, with a mini-
mum contact opening of 3 mm should be installed.
by means of a socket conforming to the regulations
in force in the country where the appliance is fitted. It
should be accessible whenever necessary; do not use
adaptors, multiple plugs or extensions.
Important
After connecting the appliance to the flexible cable, tighten
all the screws on the terminal board. Make sure jumpers
are installed according to the type of mains system as
indicated in the table.
For example: line 1 in the table
Electrical connections
Voltage
Frequency
Fuses
Sections
230V-1+N~50 Hz
25 A*
2.5 mm²
* Application of the simultaneity coefficient in accordance with
IEC 60335-2-6 norm
5
1
2
3
4
U-bolt
connection support
Phase Neutral Earth
In the event of an incorrect connection:
if your appliance does not work,
check the position of the wires in the terminal board,
check that all screws are tight,
check the positioning of the jumpers.
L N
1 2 3 4 5