CONNECTING TO GAS SUPPLY
The oven is designed to be connected with an approved appliance flexible connection
to BS 669. A length of 0.9 to 1.25m is recommended. An adaptor backplate should be
fitted in the area shown to allow the appliance to be pushed fully back into the cabinet.
The flexible hose should be fitted such that it cannot come into contact with moveable
parts of the housing unit (e.g. a drawer) and does not pass through a space where it is
likely to become trapped or damaged.
The temperature rise of areas at the rear of the appliance that are likely to come in
contact with the flexible hose do not exceed 70
o
C.
INSTALLATION INSTRUCTIONS
30
200mm
410mm
240mm
50mm
CABINETS LESS THAN 565mm
DEEP
The appliance can be fitted into a cabinet of
minimum depth 550mm providing a suitable
connection to the gas supply can be made.
The wall behind the appliance will need to
be chased away behind the appliance gas
inlet.
The gas connection can either be made with
a flexible hose or 8mm minimum diameter
rigid piping, leading below or to the sides of
the appliance. Where rigid piping is used, an
accessible isolation tap with suitable means
of disconnection must be provided to allow
for servicing.