Cres Cor CCBC12-UA-100 Refrigerator User Manual


 
[ Section 5- Troubleshooting ] [ Page 19 ]
SERVICE & TROUBLESHOOTING
Setting or Resetting Time and Date
SET UP PROCEDURE
SWITCH FUNCTION IN SPECIAL SWITCH MODE
I/O ON/OFF SWITCH
1 When held in, displays the code for current parameter
2 Step back to previous parameter, and while held in displays the parameter
code. When released, displays the value of the parameter.
3 Advance to the next parameter. (same as above)
Increase the value of the current parameter.
X
Decrease the value of the current parameter
To set the parameters complete the following steps:
1. This can onl
y
be entered from the panel OFF mode.
2. Press and
HOLD IN
any key
EXCEPT
the
ON/OFF
key for three seconds.
3.
While Holding ke
y
, press and release the
ON/OFF
key.
You will now be in the programming mode.
CODE PARAMETER
SET AT:
bss Blast Soft Stat 33
bhs Blast Hard Stat 12
bfs Blast Freeze Stat -16
sss Store Soft Stat 33
shs Store Hard Stat 33
sfs Store Freeze Stat -8
bsd Blast Soft Differential 35
bhd Blast Hard Differential 35
bfd Blast Freeze Differtial 35
ssd Store Soft Differential 35
sfd Store Freeze Differential 35
bd1 Blast Duration 1 (normally 30 min.) 30
bd2 Blast Duration 2 (normally 60 min.) 60
bd3 Blast Duration 3 (normally 90 min.) 90
bd4 Blast Duration 4 (normally 240 min) 240
cab Cabinet Number 1
ala Alarm Duration 900 (15 min)
ddc Defrost Duration for Cabinet Hex. Switch
dic Defrost Interval for Cabinet Hex. Switch
ddp N/A defrost Duration for PoD minutes, Set Manually
dip N/A defrost Interval Hours, Set Manually
det Defrost Target Temperature 39
yr Calander Year Setting Set Accordingl
y
nth Calander Month Setting Set Accordingl
y
da
y
Calander Day Setting Set Accordingl
y
hr Calander Hour Setting Set Accordingl
y
ute Calander Minute Setting Set Accordingl
y