Cres Cor CCBC12-UA-100 Refrigerator User Manual


 
[ Section 5- Troubleshooting ] [ Page 19a ]
ALARM CODES
7-Segment Display
The left hand window shows the cabinet wall temperature.
The right hand displays show the probe temperatures during a blast cycle, and are normally blank
during store. If a probe fails it will indicate pf (probe failure) during a blast.
Cab temp window also acts as a count up timer in probe blast.
If there is an alarm condition, the top probe display will show an alarm number a0 to a7
during store (see table below), but will still show the probe temperature during blast.
7-Seg Display
Alarm Condition
a0 AIR ON SENSOR FAILURE
a1 WALL SENSOR FAILURE
a2 FIN SENSOR FAILURE
a3 FOOD PROBE 1 FAILURE *
a4 FOOD PROBE 2 FAILURE
a5 FOOD PROBE 3 FAILURE
a6 SPARE
a7 POWER CUT DETECTED
* (Top Display On Front Panel Used For 3 Probe Systems)
Note: for each probe only one audible alarm and alarm printout is allowed to be issued
each day. This is to prevent excessive paper use and noise nuisance in the event of an
intermittent probe failure. However, repeated probe failures are displayed on the probe
display window, (top window in the case of 3 probe panels)