HOW TO ADJUST THE DOOR LATCH:
1. For vertical (up and down movement)
adjustment:
a. Loosen (2) screws located in magnetic
strike.
b. Move strike up or down for alignment
to magnet on latch.
c. Tighten screws to secure
2. For horizontal (greater or lesser magnetic
draw) adjustment:
a. Loosen (4) screws in door latch.
b. Move latch forward or backward to
adjust magnetism.
c. Tighten screws to secure.
HOT UNIT REMOVAL:
1. Disconnect power cord from wall outlet.
2. For half-size model: CO151HW Series,
remove screws around top cover.
3. Disconnect the yellow cord between top and
bottom, in the back of the cabinet (see
Figure 2).
4. Lift off Hot Unit.
FIGURE 2
Hot Unit Removal
REPLACEMENT PARTS: Include all information on nameplate when ordering parts.
Cabinet Replacement Parts
MODEL PRFIX CO-151, RO-151 (“Q” SERIES)
DESCRIPTION -FPWUA (12), (18) -FWUA (12), (18) -FW1332 -HWUA6 -XWUA5
Hot Unit, 208V, 1 Ph HU675013Q1 HU675025Q1 HU675029Q1 HU675037Q1 HU675037Q1
Hot Unit, 208V, 3 Ph HU675015Q1 HU675027Q1 HU675031Q1 HU675039Q1 HU675039Q1
Hot Unit, 240V, 1 Ph HU675014Q1 HU675026Q1 HU675030Q1 HU675038Q1 HU675038Q1
Hot Unit 240V, 3 Ph HU675016Q1 HU675028Q1 HU675032Q1 HU675040Q1 HU675040Q1
Door Latch Kit 1006-120-001 1006-120-01 1006-120-001 1006-120-01 1006-120-01
Door Strike 1006-120-02 1006-120-02 1006-120-02 1006-120-02 1006-120-02
Door Hinge 0519-074 0519-074 0519-074 0519-074 0519-074
Door Assembly 1221-525 1221-525 1221-543 1221-525 1221-545
Door Gasket 0861-185 0861-185 0861-184 0861-185 0861-250
Angles or Racks 0621-281-SS 0621-281-SS 1104-108 0621-281-SS 0621-281-SS
MAINTENANCE INSTRUCTIONS