Dacor DR30EIFS Range User Manual


 
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Distinctive
30” Wide
Electric Ranges
Document # PG05-008
Revised 11/09/12 Page 3/4
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
* To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm), with the width at the
notches remaining 30 1/16”. This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed.
Countertop height: 34 3/4” (88.3 cm) min.
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
TOP VIEW - SLIDE-IN, SELF-RIMMING INSTALLATION, 3”
SIDE PANELS REMOVED
TOP VIEW - SLIDE-IN, SELF-RIMMING INSTALLATION, 3”
SIDE PANELS INSTALLED
Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only)
Electrical Specifications
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (9.5 mm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
19 7/8”
(50.5 cm)
to
22 7/8”
(58.1 cm)
19 7/8”
(50.5 cm)
24 1/2”
(62.2 cm)
max.
Countertop front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (9.5 mm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
22 7/8”
(58.1 cm)
24 1/2”
(62.2 cm)
max.
Countertop front
10” (25.4 cm)
10” (25.4 cm)
12” (30.5 cm)
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
1” (2.5 cm)
UTILITY CLEARANCE BEHIND RANGE
NEMA 14-50P PLUG NEMA 14-50R RECEPTACLE
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
Total Connected
Load**
240 Vac 60 Hz, 4 wire*,
50 Amp.
11.94kW (49.75 Amp.)
*Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.
**This information above is for reference only. If the above data
does not agree with the product data label, use the data on the
product data label.
IMPORTANT: Models DR30ES-C and DR30EFS-C are
freestanding ranges that come with a factory installed 4-wire
appliance cord and NEMA 14-50P plug. This wiring configuration
is required for freestanding ranges installed in Canada, although
they may be used elsewhere, if local codes permit. The plug
is designed to plug directly into a NEMA 14-50R electrical
receptacle installed by a licensed electrician according to the
above specifications.
Factory Wiring
Model Factory Electrical Connection
DR30ES Power cord not installed. Not for installation in Canada.
DR30ES-C
Cord connected, for installation in Canada and U.S.A.,
where local codes permit.
DR30EFS No power cord. Not for installation in Canada.
DR30EFS-C
Cord connected, for installation in Canada and U.S.A.,
where local codes permit.
DR30EIS No power cord. May be installed in Canada and U.S.A.