Electrical Requirements
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only 15 or 20 Amp. fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an extension
cord.
IMPORTANT: If this product is connected to a GFCI (ground fault
circuit interrupter) equipped outlet, nuisance tripping of the power
supply may occur, resulting in loss of cooling. Food quality and
flavor may be affected. If nuisance tripping has occurred, and if
the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect power at the circuit breaker
box.
When you are finished, turn ON the main power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.
Installation Requirements
Locate the refrigerator so that it may easily be pulled out from
the wall if service becomes necessary.
A grounded 3 prong electrical outlet should be placed as
shown in the illustration below. See Electrical Requirements
for more information.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor or
the back wall. See Water Supply Requirements for more
information.
Model Cutout Width A Dimension B
DYF42BIWS
41½” (105.4 cm) to
41¾” (106.0 cm)
10”
(25.4 cm)
DYF48BIWS
47½” (120.7 cm) to
47¾” (121.3 cm)
16”
(40.6 cm)
NOTE: Flooring under refrigerator must be at same level as the
room. The face of the cabinetry must be plumb.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
83
¹/2
"
(212.1 cm) min.
84
³/4
"
(215.3 cm) max.
to bottom of solid soffit
77
"
(195.6 cm)
A
(see chart following)
24"
(61.0 cm) Min.
B
See page 5
83 1/2” (212.1 cm) min.
84 3/4” (215.3 cm)
to bottom of solid soffit
77”
(195.6 cm)
B
Dimension
A
(see chart following)
24”
(61.0 cm) min.