Dacor ECS130 Oven User Manual


 
8
in s T a l l a T i o n in s T R u C T i o n s
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Separate No. 10 (minimum)
copper grounding wire
Clamp must be
tight on pipe
No. 4
copper wire
Metal
water pipe
Clamps
Bare metal
Meter
Connecting the Appliance Ground to a Grounded Junction Box Wire or Cold Water Pipe.
WARNINGS
1. Do not ground the appliance to a gas supply pipe or hot
water pipe.
2. Do not turn on power to the appliance until the oven is
permanently grounded.
3. Grounded cold water pipe must have metal continuity
to electrically ground and must not be interrupted by
insulating materials. Any insulating materials must be
jumped as shown below with a length of No. 4 copper
wire securely clamped to bare metal at both ends.
Lift the wall oven up to the cabinet cutout, using the upper edge of the
cavity opening and the bottom of the oven case side as gripping points.
Use extreme caution when lifting the appliance as it is heavy. Be certain to
take all necessary safety precautions.
Resting the oven on the cabinet-mounting platform, slide the oven into
the recessed area until the rear edge of the oven frame is flush with the
cabinet face and the oven is centered within the cutout. Ensure that the
electrical conduit slides through the opening in the cabinet platform or
coils above the oven chassis as the oven is slid into place. The cable
must be placed into the recessed area located along the rear vertical edge
of the oven or coiled above the oven chassis. Do not trap the appliance
cable between the oven case back and the rear wall.
WARNING
1. Failure to install the mounting screws may result
in movement or tipping of the oven during use and
personal injury.
2. Do not block the oven air exhaust located at the bottom
of the oven. Blocking the intake may cause cabinet
damage and poor baking performance.
mo u n T i n g T h e ov e n
Oven Gripping Points
C. Connecting the Green Appliance Wire to a
Grounded Junction Box Wire or Grounded Cold
Water Pipe – Where Local Codes Permit
1. Separate the green and white appliance wires.
2. Connect the black appliance wire to the black (L1) power supply wire
in the junction box.
3. Connect the red appliance wire to the black (L2) power supply wire in
the junction box.
4. Connect the red appliance wire to the red (L2) power supply wire in
the junction box
5. Connect the green appliance wire to a grounded wire in the junction
box or to a grounded cold water pipe.
6. If connecting to a grounded cold water pipe, a separate copper
grounding wire (No. 10 minimum) must be connected to a grounded
cold water pipe by means of a clamp and then to an external
grounding connector screw.
For the single ovens and the upper cavity of the double ovens, locate the
mounting holes found in the sides of the oven frame. Using a 1/16” drill,
drill four pilot holes for the #6 x 3/4” screws provided in the instruction
envelope. Install the screws through the oven frame and into the cabinet
to secure the oven. Do not over-tighten the screws.
Repeat the mounting procedure for the lower cavity if installing a double
oven.