Before You Call For Service
Problem Solution Guide
PROBLEM MAY BE CAUSED BY WHAT TO DO
Nothing Works. Control panel is not lit.
Fan does not work.
Power to hood is off.
Turn on power at junction or fuse box.
Check for tripped breaker or blown
fuse.
Power outage. Call electric company.
Hood not connected to electric power. Have qualified electrician connect
hood to electric power.
Lights do not work. Control panel is not
lit.
See Nothing Works above.
Light does not work. Control panel is lit. Loose light bulb. Check to make sure that the light bulb
is screwed in completely (see
page 6).
Light bulb burned out. Replace light bulb (see page 6).
Fan does not draw heat and smoke
properly.
Fan set to low setting. See Operating Instructions section.
Filter(s) clogged or dirty. Check filters. Make sure they are
completely clean and not blocked by
foreign objects.
Damper jammed shut or duct work
clogged.
Consult with a qualified installation
professional.*
Fan shuts off by itself.
Timed feature used. If the timer is set, the fan will turn off
after ten minutes. See Timed Feature
on page 4.
Fan does not work. Control panel not lit. See Nothing Works above.
Fan does not work. Control panel lit. Fan malfunction. Call for service.
Fan comes on by itself.
Hood AUTO-ON feature. The fan comes on automatically
when the temperature rises above
140°F (60°C). The AUTO-ON feature
protects the control panel from
damage due to overheating. The
fan will automatically turn off when
the temperature goes below 140°F
(60°C), if the fan control is set to “off”.
This safety feature cannot be turned
off. See page 4 for more details.
* The duct work connected from the range hood chimney to outside the house or building required to vent heat and
smoke is not manufactured, warranted or serviced by Dacor. The customer is responsible for having a qualified installer
install and maintain the duct work.