Dacor EORD227 Oven User Manual


 
6
Installation Specifications
Installation Planning
WARNING
Observe all governing codes and ordinances during plan-
ning and installation. Contact your local building depart-
ment for further information.
IMPORTANT
Locate the junction box so that the oven may be easily •
disconnected in the event that it needs to be removed
from the wall completely for service.
If the oven is not installed level it may deliver poor or •
inconsistent baking results.
A qualified technician must complete the installation of •
this built-in appliance. Proper installation is the respon-
sibility of the customer.
Carefully check the location where the oven is to be •
installed. The oven should be placed for convenient
access. Make certain that electrical power, meeting
the specifications on page 4, can be provided in the
selected location.
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Dacor recommends installing the electrical junction box •
in the one of the locations shown.
Install the junction box in a location that allows the oven •
to be removed from the the cut out for service without
being disconnected.
Plan the installation so that all minimum clearances are •
met or exceeded. Dimensions shown provide mini-
mum clearances, unless otherwise noted. Be certain
that proper clearance is provided for the oven door
when it is in the open position according the Product
Dimensions.
Cabinet cutout dimensions must be used as indicated.•
The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
All contact surfaces between the appliance and the cabi-•
net must be solid and level.
Provide a platform within the cabinet to support the •
oven. It must be installed level and straight. The top
edge of the platform must be flush with the cut out at
the front of the cabinet. There are no provisions to level
the oven after it has been installed. 3/4” (1.9 cm) thick
plywood is recommended.
Model
Number
Minimum Cabinet
Width (N)
Minimum Cut Out
Width (P)
Minimum Cut out
Height (R)
EORS127/
MORS127
27” (68.6 cm) 25 ½” (64.8 cm)
27 5/8” (70.2 cm)
EORS130/
MOCS130
30” (76.2 cm) 28 ½” (72.4 cm))
EORS136 36” (91.4 cm) 34 ½” (87.6 cm) 27 ¾” (70.5 cm)
EORX227/
MORX227
27” (68.6 cm) 25 ½” (64.8 cm)
49 1/8” (124.8 cm)
EORX230/
MORX230
30” (76.2 cm) 28 ½” (72.4 cm)
Cabinet Dimensions
X = Number of convection ovens, see page 3