Dacor ER30G Range User Manual


 
5
Planning the Installation
Any openings in the wall behind the appliance or in the •
floor underneath it must be sealed.
Both the gas supply piping and shut-off valve and the •
electrical outlet must be located so they do not interfere
with the range when it is installed.
All dimensions shown are based on standard American •
cabinets 36 inches (914mm) high at the finished
countertop by 24 inches (610mm) deep, with a 25
inch (635mm) overall countertop depth. All minimum
clearances shown MUST be maintained.
If cabinet storage space is to be provided directly above •
the range, the risk of personal injury may be reduced by
installing a ventilating hood that projects horizontally a
minimum of 5 inches beyond the face of the cabinets.
The installation must allow for the following:•
Access to the gas shut-off valve when the unit is ◊
installed.
Access to the electrical outlet, when the range is in ◊
place.
The gas supply piping, gas shut-off valve and the ◊
electrical junction box or receptacle must be located
so they do not interfere with the range when it is
installed.
The electrical outlet and gas shut off valve must ◊
be located so that the range can be pulled out for
service while the appliance remains connected.
Cabinet Layout
WARNING
Failure to meet or exceed the minimum dimensions
stated below may result in a fire hazard.
Carefully check the location where the range is to be •
installed. For best performance, the range should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce •
accumulated smoke in the room, Dacor strongly
recommends installing a range hood. A range hood
should project horizontally a minimum of five (5) inches
beyond the face of the cabinets.
The range may be installed flush to the rear wall. •
Dacor highly recommends installing a non-combustible
material on the rear wall above the range and up to the
vent hood. It is not necessary to install non-combustible
materials behind the range below the countertop height.
Regardless of the type of back wall surface, the range •
must not be installed or operated without the backguard
in place.
**
** Cabinet depth is at discretion of customer
but cabinet face MUST NOT protrude further
than rear of front panel, see product dimesions
*** Consult local code for exact location
requirements.
* Vertical to combustible surface
B
A
Non-Combustible
surface along
back wall
recommended
Suggested
location of
utilities***
30” (762mm)
min.*
A B
30 1/16”
(764mm)
36” (914mm)
Recommended
30” (762mm)
Minimum
Cutout Dimensions