Dacor RDW24S Dishwasher User Manual


 
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
RDW24I, RDW24S
Renaissance 24” Wide
Built-In Dishwasher
Document # PG10-007
Revised 03/12/12 Page 3/3
EXAMPLE OF DRAIN CONNECTION WITHOUT AIR GAP
EXAMPLE OF DRAIN CONNECTION WITH AIR GAP
Drain Specifications
IMPORTANT: Should a drain hose longer than the one provided be
required, use a hose extension approved for detergents and high
temperature water. Total drain hose length (including factory installed
hose) must not exceed 10 feet. (304.8 cm) from the top of the drain loop
on the back of the unit. Joints and joint tubes must have a minimum inside
diameter of 7/8” (2.2 cm).
The drain hose supplied with the dishwasher must be connected to
a minimum 1/2” inside diameter drain connection. The drain hose is
equipped with a cone-shaped connector on the end that is ready to be
cut to the desired drain connection size. Only a clamp (not provided)
is required. It fits drain connections with an internal diameter of 1/2,
5/8, 3/4 and 7/8 inches (1.3, 1.6, 1.8 and 2.2 cm).
You must install an air gap in the drain system if required by local
codes. Plan for the air gap in the sink or countertop area adjacent to
the dishwasher. A section of drain hose (not provided) needs to be
installed from the air gap to the waste disposer inlet or waste tee. See
below.
If an air gap is not required, the drain hose must be installed to a
disposer inlet or waste tee above the sink trap in the household
plumbing.
For proper drainage, the drain line connection must be a minimum
of 20” (50.8 cm) above the bottom of the dishwasher. No part of the
drain hose can be lower than the disposer or waste tee connection or
higher than 35” (88.9 cm) from the bottom of the dishwasher.
20"
min.
35"
max.
35"
max.
20"
min.
G
H
J
Custom Panel/Handle for Model RDW24I
The custom panel mounting screws are provided with the dishwasher.
Follow the panel dimensions below to ensure that the custom overlay
panel will fit properly.
The handle and handle mounting hardware are not included with
model RDW24I. A handle designed for use with an appliance should
produce satisfactory results. Do not use a knob or handle attached
by a single fastener. Instead use a handle with a larger D-style
pull. The panel craftsman must determine and obtain the proper
handle fasteners for the application. Handle screw heads must be
countersunk into the panel before panel installation.
(G) Height (H) Width (J) Thickness
30 1/8” (76.5 cm) 23 3/4” (60.3 cm)* 3/4” (1.9 cm) min.
* Based on 24” (61.0 cm) wide cutout. Recommended panel width is 1/4”
(6.4 mm) less than cutout width.
IMPORTANT: If the door panel weighs more than 15 pounds, you must
order the optional heavy duty door springs (Dacor PN 701385). Maximum
panel weight with heavy duty springs: 23 pounds.
CUSTOM PANEL
DIMENSIONS