Daewoo 181GOA0A Microwave Oven User Manual


 
CONDITION CHECK
Check continuity of magnetron
Defective
magnetron
RESULT
No
Continuity
CAUSE REMEDY
Replace
Outlet has
proper
voltage Fuse
does not
blow.
CONDITION CHECK
Check continuity of primary
interlock switch
Malfunction of
primary interlock
switch
RESULT
No
Continuity
CAUSE REMEDY
Adjust or
replace
Turn table
motor and
oven lamp
do not turn
on
Check continuity of secondary
interlock switch
Malfunction of
secondary
interlock
switch
No
Continuity
Adjust or
replace
Check D.C. voltage being
supplied to RELAY (RY2) coil
Defective touch
control circuit
0 V Replace
Faulty contacts of
RELAY (RY2) or
open relay coil
Approx.
15 VDC
Replace
Display do not shown
countdown
Malfunction of
secondary
interlock switch
Replace
Check continuity of
power supply cord
Open power
supply cord
No
Continuity
Replace
Defective touch
control circuit
Normal
Replace
NOTE1
All these switches must be replaced at the same time, please refer to Interlock Mechanism And Adjustment .
(TROUBLE 2) Display shows all figures selected, but oven does not start cooking, even though desired program and
time are set and start pad is tapped.
20