11
6. To remove high voltage capacitor.
(1) Remove a screw which secure the groun-
ding ring terminal of the H.V.diode and
the capacitor holder.
(2) Remove the H.V. diode from the capacitor
holder.
(3) Reverse the above steps for reassembly.
l High voltage circuit wiring
7. To remove magnetron.
(1) Remove a screw which secure the
magnetron.
(2) Remove the magnetron.
(3) Reverse the above steps for reassembly.
CAUTION : Never install the magnetron without the metallic gasket plate which is packed
with each magnetron to prevent microwave leakage. Whenever repair work is carried out
on magnetron, check the microwave leakage. It shall not exceed 4mW/cm
2
for a fully
assembled oven with door normally closed.
Magnetron antenna
Metallic
gasket
plate
Cooling fin
Filament
terminal