Defy Appliances DCH262 Ventilation Hood User Manual


 
Page 4
Installation.
Note:The extractor hood is intended to
hang from a horizontal ceiling capable of
supporting the weight of the hood.
(approximately 40 kg)
Step 1
Carefully unpack the extractor hood and
component parts.
With the assistance of a qualified in-
staller, mount the top extension adaptor
to the ceiling above the cooking surface.
Cut a hole in the ceiling (where applica-
ble) to accept a power supply cord with
a fitted plug and an outlet pipe
Step 2
Fit and secure the square tubes into the
four recesses on the extractor hood, as
shown, using the M8 bolts supplied.
Step 3
Slide the lower chimney duct onto the
extractor hood as shown.
Slide the top chimney duct ( the one
with the louvers) into the lower chim-
ney duct.
Step 4
Remove the grease filters and lift the
extractor hood assembly and slot it into
the top extension adaptor.
Adjust to a suitable height.
(minimum 750mm above the cooking
surface).
Tighten the clamping bolts to hold the
extractor in place.
Connect the outlet pipe if required and
insert the fitted plug into the 15A
socket.
Step 5
Slide the upper chimney duct into place
against the ceiling.
Fasten from the side.
Fasten the lower chimney duct to the
extractor hood from underneath the ex-
tractor as shown.
Replace the grease filters.
3 X M8
BOLTS ON
EACH SIDE
CLAMPING
BOLTS
1
2
3
4
5
2 SELF TAPPING
SCREWS
4 SELF TAPPING SCREWS
CEILING