10mm
Installation
Installation sequence;
1. Extractor unit / chimney brackets.
2. Top chimney duct.
3. Bottom chimney duct.
• Carefully remove the extractor hood and
the components from the packaging.
• Carefully remove the protective film.
• Remove the grease filters (see page 8).
• Draw a fine vertical line on the wall from
the rear-centre of the hob to the ceiling.
• Draw another line, horizontal this time,
where the bottom edge of the hood
should be.
• (A minimum clearance height of 650 mm
is required when installed above a built
in electric hob or 700 mm when installed
above a built in gas hob).
• For mounting the chimney bracket,
drill 2 holes, 5 mm diameter and 45 mm
deep into the wall.
• For mounting the extractor hood, drill
2 holes, 8 mm in diameter and 60 mm
deep as indicated on the mounting
diagram.
• Push the 5 mm wall plugs through the
holes in the chimney mounting brackets.
Insert the plugs into the drilled holes
together with the chimney mounting
bracket and fasten securely.
• Push the 8 mm wall plugs into the 8 mm
holes ensuring that they are flush with the
wall.
• Partially screw two 6 mm screws into the
two top wall plugs leaving them to
protrude about 10 mm.
• Lift and hook the extractor hood over and
onto the two protruding screws through
the key-hole slots provided at the top of
the extractor hood frame.
• Place slotted washers between the
extractor hood frame and the protruding
screw heads.
• Before fitting the chimneys, connect
up the outlet ducting (if required) and
insert the fitted plug into the wall
socket.
• Remove the protective film from the
chimney ducting taking care not to
damage the polished stainless steel
surface.
• Fit the upper chimney duct section (the
one with louvre outlets) to the ceiling
mounting bracket using the screws
supplied.
• The lower duct fits between and over
the extractor hood motor assembly and
the upper duct. Take care not to scratch
or damage the hood and upper duct
surfaces.
• Loosely attach the lower duct bottom
edge to the hood by four self tapping
screws through four holes on the inside
of the extractor hood.
• Fit the lower duct to the lower chimney
wall mounting bracket and tighten the
four self tapping screws on the inside of
the extractor hood.