Delfield 6100XL Refrigerator User Manual


 
6000XL Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 733-8821, Fax (888) 779-2040, www.delfield.com
2
Delfield
®
Serial Number Information ........................................................2
Receiving & Inspecting Equipment ...........................................2
Specifications .............................................................................3
Installation ...............................................................................4-5
Operation ....................................................................................6
Maintenance ............................................................................7-8
Wiring Diagrams ...................................................................9-13
Refrigeration Package Diagram ...............................................14
Replacement Parts ..............................................................15-16
Standard Labor Guidelines ......................................................17
Standard Warranties ...........................................................18-19
The serial number of all self-contained 6000XL Series
refrigerators and freezers is located above the door under the
shroud.
Always have the serial number of your unit available when
calling for parts or service. A complete list of authorized
Delfield parts depots is available at www.delfield.com.
This manual covers standard units only. If you have a custom
unit, consult the customer service department at the number
listed below.
©2010 The Deleld Company. All rights reserved. Reproduction without written
permission is prohibited. “Deleld” is a registered trademark of The Deleld
Company.
Contents
Serial Number Information
Even though most equipment is shipped crated, care should
be taken during unloading so the equipment is not damaged
while being moved into the building.
1. Visually inspect the exterior of the package and skid or
container. Any damage should be noted and reported to
the delivering carrier immediately.
2. If damaged, open and inspect the contents with the
carrier.
3. In the event that the exterior is not damaged, yet upon
opening, there is concealed damage to the equipment
notify the carrier. Notification should be made verbally
as well as in written form.
4. Request an inspection by the shipping company of the
damaged equipment. This should be done within 10
days from receipt of the equipment.
5. Be certain to check the compressor compartment
housing and visually inspect the refrigeration package.
Be sure lines are secure and base is still intact.
6. Freight carriers can supply the necessary damage forms
upon request.
7. Retain all crating material until an inspection has been
made or waived.
Receiving And Inspecting The Equipment
NOTE: Upon powering unit, there could be up to a
10 minute delay before unit begins to cool.