5. Check the minimum burner setting by quickly rotating the gas control knob from
the maximum to the minimum position, the flame must not go out. If adjust-
ment is required carry out the “minimum burner setting adjustment" procedure
described below.
6. If satisfactory performance cannot be obtained, the installer shall check the instal-
lation and notify the local gas supply authority for a gas supply problem, or if it
is an appliance problem, our Customer Service Centre should be called to obtain
the nearest authorized Delonghi Service Agent.
7. Where the appliance data plate cannot be easily read with the appliance in the
installed position the duplicate data plate must be attached to adjacent surface
and the duplicate Natural gas / ULPG conversion label should also be included
where a Natural gas / ULPG conversion has been completed.
Figure 10
10
INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY
■ If this appliance has to be installed with a hose assembly, the installer shall refer
to the network operator or gas supplier for confirmation of the gas type, if in
doubt.
■ Flexible hose assemblies should be AS/NZS 1869 Class B or Class D certified.
The thread connection shall be Rp 1/2” (ISO 7-1) male
.
■ IMPORTANT WARNING: After connection the installer must check that the
hose is not kinked, subjected to abrasion or permanently deformed.
The installer must check also that the hose is not near (or in contact) with any hot
surfaces e.g. base of metal hotplate, underbench oven etc.
■ The hose assembly shall be as short as practicable and comply with relevant
AS5601 / NZS5261 requirements.
■ IMPORTANT WARNING: The installer shall ensure the hose assembly is
restrained from accidental contact with the flue outlet of an underbench oven.
■ When used with a flexible hose, the connector on the wall should be between
800 mm to 850 mm above the floor and in the region outside the width of the
appliance to a distance of 250 mm.
The supply connection point shall be accessible with the appliance installed.