Dometic RM36O Refrigerator User Manual


 
5
CLEARANCES
Minimum clearances in inches to combustible
materials are:
G:
Top 0
K:
Side 0
L:
Bottom 0
M:
Rear 1
Clearance M between the rear-most part of the
refrigerator and the wall behind the refrige-
rator.
Clearance N on top of the condenser is related
to the minimum ventilation height.
See Fig. 5 and examples below.
Fig.5
MEASUREMENTS
Distance
Refrigerator Overall
Installation
Recess
between top
dimensions
dimensions
dimensions
of condenser
model
to top of
Height Width Depth
Height
Width Depth
Height Width
Depth
refrigerator
A
B
C
h
W
d
H
W
D
e
RM360
30
3/8
21
11/166
22
1/16
29
9/16
20
1/4
20
3/166
29
3/4
20
1/2
21
3/16
1
1/4
RM460
32
15/166
23 24
11/166
32
1/8
21
9/16
22
3/4
32
5/166
21
13/166
23
3/4
1
1/4
RM660
40
13/166
23 24
11/166
40 21
9/16
22
3/4
40
3/166
21
13/166
23
3/4
1
1/4
RM760
52
23 24
11/16
51
3/16
21
9/16
22
3/4
51
3/8
21
13/166
23
3/4
1/8
Storane volumes
Refrigerator Total storage volume in cu ft
model
RM360
3.0
RM460
3.9
RM660
5.1
RM760
6.0
EXAMPLES
The clearance N for the
RM360
model is derived
in the following way:
at
A.
Installation with upper and lower side vents.
N=Minimum ventilation height 37 minus in-
stallation height 29
9/16
plus distance
between condenser top and refrigerator top
1
l/4
N=37-29
9/16+1
l/4=8
11/16.
B.
Installation with roof vent and lower side
vent.
N=Minimum ventilation height 31 minus in-
stallation height 29
9/16
plus distance
between condenser top and refrigerator top
1
l/4
plus distance between roof surface
and roof vent cap 5
l/4.
N=31-29
9/16+1
l/4+5
l/4=7
15/16.
Fig.6