CARE AND CLEANING
Charcoal Filter(Optional) Replacement
If your oven is vented inside, the charcoal filter needs replacing every 6 to 12 months, and more often if
necessary. The charcoal filter removes odors and smoke from the vented air. If you start smelling
cooking odors or see some smoke, you need to replace the charcoal filter. Here's how:
1. To order a new charcoal filter, contact your dealers parts department.
2. Remove the two vent grille mounting screws.
If the screws are not accessible, remove the oven from the wall.
3. Tip the grille forward, then lift it out.
4. Lift the back of the charcoal filter and slide it toward you.
5. Slide a new charcoal filter into place.
6. Put the grille back on with the mounting screws.
Work Light Replacement(Cooktop/Countertop Light)
When either bulb in the work light burns out, you will need to replace it with a 30 watt appliance bulb.
1. Disconnect the power at the circuit breaker or unplug the power cord.
2. Remove the phillips head screw from the work light cover. Right side will drop.
3. Unhook tab at left side.
4. Unscrew the burned out bulb and replace with one of the same size and wattage (30 watts).
5. Replace the work light cover and the screw.
6. Reconnect the power.
7. Set the Time of Day (see Page 9).