Dometic RGE400 Refrigerator User Manual


 
TROUBLESHOOTING
The Refrigerator Does Not Cool Properly
1.
2.
3.
4.
5.
6.
7.
8
9
10
11.
Burner jet clogged. Clean. See Section Maintenance
& Service, Item 2. Periodic Maintenance, Paragraph
E. Item 1-14.
Check level of refrigerator.
Restriction in air flow across cooling unit.
Heavy frost build-up on evaporator fins.
Defrost.
Flue baffle not inserted properly in flue tube.
Improperly set thermostat.
See paragraph on thermostat. In hot weather the
setting should be closer to
“MAX”
than usual.
Burner dirty.
Clean. See Section Maintenance
&
Service, Item 2.
Periodic Maintenance, Paragraph E. Item 7.
LP gas pressure low at burner.
Set main regulator so pressure does not drop below
11
inches water column at pressure test port.
Burner not located properly under flue tube.
Relocate.
Burner damaged
Replace.
Odors and fumes.
1.
Dislocated burner.
2. Damaged burner.
3. Dirty flue tube.
REFRIGERATOR DIMENSIONS
Overall dimensions in inches and (mm):
Model No. RGE 400
Height
63-15/32
(1612)
Width
23-5/16
(592)
Depth
24-l/2
(623)
Total refrigerator volume: 7.3 cu.ft.
F
SPARE PARTS
The following list is a list of commonly used parts which
should be available, if required, from your
Dometic
Service Center.
Part No.
Description
200
74
19-21
/7
Jet, no. 58
200
75
03-03/6
Burner, (with electrode)
293
0379-00/9
Electrode
293
14
96-04/2
Thermocouple
200
75
05-00/7 Cover, (burner)
293
1657-01/5
Safety valve
200
71
99-04/1
Thermostat
200
7423-00/3
Piezo
igniter
293
26
67-04/7
Baffle
17
37
42-27/1
Heater,325W,120V
293
21
06-01/2 Lamp cover
293
2575-01/8
Door shelf
293
2576-01/6 Door shelf, 3 pieces
200
7480-32/6 Knob thermostat
200
74
80-35/9
Knob (On/Off)
293
2783-01/8 Flap, base front
Contact an authorized service center for
parts and repairs as needed.
293 29 32
1
1
@-WHITE
@-BLACK
@-GREEN
&FLOW/GREEN
*HEATER
@-SWITCH
@-THERMOSTAT
@TERMINAL
BLOCK
@--SWITCH
LIGHT
&%:RY
BOX
6V
I
120 VOLTS AC