Dometic RGE 2000 Refrigerator User Manual


 
7
Placing the gas bottle
Gas bottles have to stand up straight.
Place the gas bottle well-ventilated.
Place the gas-bottle, where it can be easily recognized in case of a fire.
The distance between the gas bottle and the fridge must not exceed 1,5m.
Only use bottle types and pressure regulation device that are valid in the particular
country.
Electrical connection
The power must be supplied via a properly earthed socket outlet.
It is advisable to run the incoming supply through an automatic circuit
breaker. The supply voltage must correspond to the value specified on
the data plate. Any difference in values may result in damage the
appliance. The power cable must be laid in such a way that it does not come in
contact with hot components of the unit/burner or with sharp edges.
If the connection cable is damaged it must be replaced by the Customer
Service at Dometic, or by respectively qualified personnel, in order to pre-
vent any hazards.
Gas connection
The refrigerator should only be operated using liquid gas (propane, butane).
Do not use town gas or natural gas.
The correct connection of the fridge has to be carried out by a skilled specialist.
Note the particularly valid national rules for usage of LG-driven appliances.
Technical Standards EN 732
A preset pressure regulator A has to be installed within the supplying line to the
fridge. The fridge must not be operated with any other pressure than the one
indicated on the rating label.
The fridge has to be connected to the gas bottle with a security hose pipe.
Choose a sufficient length to connect the hose pipe without kinks. The hose must
not be longer than 1.5 m.
The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
5.1.1
5.1.2
5.1.3
Source:
Fa. GOK, Marktbreit
A
SW 14
SW 17
A
bottle valve