Dometic RM2354 Refrigerator User Manual


 
5
VENTILATION HEIGHTS
Refer to FIG. 3a, 3b and 4.
CLEARANCES
Minimum clearances in inches to combustible materials
are:
G: Top 0
K: Side 0
L: Bottom 0
M: Rear 1
N: See NOTE: “N” below.
NOTE: Clearance “M” is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Ventilation height “N”
With upper and lower side vent is “N” the distances be-
tween the bottom of the lower side vent to the top of the
upper side vent.
With roof vent and lower side vent is “N” the distance
between the bottom of the lower side vent to the roof
material.
For ventilation height, see table VENTILATION
HEIGHTS.
See Figures 3a, 3b and 4.
This method of installation and these clearances will give you adequate space for service and proper installation.
Refrigerator Minimum ventilation heights in inches and mm.
model
installation with Installation with roof
RM2354 upper and lower vent and lower side
side vent vent
inch 34 31
mm 864 787
Overall Recess
Refrigerator Dimensions Dimensions
Model
Height Width Depth Height Width Depth
ABCHWD
RM2354 inch 30-5/32 21-7/8 22-23/32 29-3/4 20-1/2 21-3/8
mm 766 556 577 756 521 542
Side view View from above
FIG. 5
D
HA
W
D
B
C
G
FIG. 4
KK
L
N
M
N
M