INSTALLATION INSTRUCTIONS
Testing LP gas safety shut off
The gas safety shut off must be tested after the refrigerator is
connected to LP gas supply.
RM2354-2454-2554-2662-2663-2862-3862 &NDR1062
To test the gas safety shut off, follow these steps:
Start the refrigerator. Switch to GAS mode.
Check that the gas fl ame is lit and the GAS mode
indicator lamp is on.
Close the manual gas shutoff valve at the back of the
refrigerator.
Wait for approx. 6 minutes. The CHECK indicator
lamp should be lit and the GAS mode indicator lamp
should be off.
Remove the protection cover.
Open the manual gas shutoff valve. Do not change
any button positions on the control panel.
Apply a non corrosive commercial bubble solution
to the burner jet orifi ce. No bubbles should appear at
the opening of the burner jet orifi ce. The presence of
bubbles indicates a defective gas safety shutoff, and
service is required.
If no bubbles are present at the burner jet orifi ce,
rinse it with fresh water. Be careful not to damage
the burner jet orifi ce.
Put back the cover.
Press the ON/OFF button once to turn the refrigera-
tor off and then press it again to turn the it back on.
Normal operation of the burner should return.
Allow the burner to operate for a minimum of fi ve
minutes.
RM2351-2451-2551-2652-2852
To test the gas safety shut off, follow these steps:
Start the refrigerator without connecting to
120 V AC.
Check that the gas fl ame is lit. In AUTO mode the
AUTO mode indicator lamp is on.
Then, follow steps 3-11 in instruction above.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
1.
2.
3.
Electrical connection
120 V AC connection
The refrigerator is equipped with a grounded three-prong plug
for protection against shock hazards. It should be plugged di-
rectly into a properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug!
The free length of the cord is 2 feet. It should be routed to
avoid direct contact with the burner cover, fl ue cover or any
other components that could damage the cord insulation.
To allow easy access through the vent door, it is recommended
that the receptacle is placed:
To the left of the refrigerator. (On the opposite side of the
refrigerator burner assembly.)
3”
above the refrigerator mounting fl oor
(
RM2662-2663- 2862-3862 & NDR1062
).
4-6”
above the refrigerator mounting fl oor
(
RM2351-2354
)
6”
above the refrigerator mounting fl oor
(
RM2451-2454- 2551-2554-2652-2852
).
120 Volt AC
receptacle
3” / 6” from the bottom
of the plastic receptacle
above the fl oor
120 V AC
120 V AC
receptacle