Dometic RM 4361NDM Refrigerator User Manual


 
6. If the refrigerator fails to work on 230/ 240 V, check:
That the 230 V supply is connected to the
refrigerator.
That the fuse is intact.
If the refrigerator is not cold enough it may be
because:
1. The ventilation is inadequate owing to reduced area
of the ventilation passages (partial blockage of
grilles from wire mesh etc).
2. The evaporator is frosted up.
3. The temperature control setting is incorrect.
4. The gas pressure is incorrect - check the pressure
regulator at the gas container.
5. The ambient temperature is too high.
6. To much food is loaded at one time.
7. The door is not properly closed or the magnetic
sealing strip is defective.
8. More than one source of energy is used at the
same time. If the refrigerator still does not work
properly, call a service technician.
The sealed cooling system must not be ope-
ned, since it contains corroding chemicals
under high presurre.
MAINTENANCE
Inspect the gas hose periodically for cracks or deep
chafing marks. Connections can be tested for leaks
using a soap solution. Do not use a naked flame! If
there is any suspicion of damage, call for a service
technician. The cooling unit behind the refrigerator
should be cleaned with a brush from time to time, but
make sure that the refrigerator is switched off when
doing this. We recommend that a service technician
check the refrigerator once a year.
SOME USEFUL HINTS
Make sure that:
The refrigerator is not operating on 12 V when the
vehicle is parked, otherwise you will drain the car
battery in a short time.
Defrosting is carried out periodically.
The refrigerator is left with the door(s) ajar when it
is not to be used for some time.
Liquids or items with a strong odour are well
packaged.
The ventilation openings are unobstructed.
The door is secured by means of the travel catch
when the caravan is on the move.
Only one mode of operation at a time is used to
run the refrigerator.
GUARANTEE AND SERVICE
Warranty arrangements are in accordance with EC
Directive 44/1999/CE and the normal conditions appli-
cable for the country concerned. For warranty or other
servicing, please contact our Dometic Service depart-
ment. Any damage due to improper use is not covered
by the warranty. The warranty does not cover any
modifications to the appliance or the use of non-origi-
nal Dometic parts; the warranty does not apply if the
installation and operating instructions are not adhe-
red to and no liability shall be entertained. Parts can
be ordered throughout Europe from our Dometic
Service department. Your Service Centre contact
numbers are found in the European Service
Network booklet. When contacting Dometic Service,
please state the model and product number, serial
number and MLC, if applicable. You will find this
information on the data plate inside the refrigerator
.
TECHNICAL DATA
Overall dimensions, refrigerator
Height 826 mm
Width 486 mm
Depth (incl. cooling unit)
without door 498 mm
with door 610 mm
Build-in dimensions
Height 830 mm
Width 490 mm
Depth 510 mm
Capacity
gross 103 lit.
net 98 lit.
frozen food compt 6,5 lit.
Weight (without packaging) 28 kg
Electrical data
Input 230 V 135 Watt
12 V 130 Watt
Energy consumption /24 h 2,1 kWh
LP gas data
Input 252 Watt
Energy consumption /24 h 0,27 kg
Cooling medium Ammonia (R 717)
LP GAS CONNECTION
The refrigerator is designed for operation on LP gas
of Butane or Propane.The refrigerator is not designed
for operation on town gas or natural gas.
The gas installation should only be carried out by a
person experienced in gas fitting. It is recommended
that the gas pipe feeding the refrigerator is run
underneath the caravan and is so arranged that it is
possible to turn off the supply to all appliances inclu-
ding the refrigerator
when they are not required. The supply pipe should
preferably be of copper. If any other material is used,
it must be of a type approved for use with conti-
nuously operating bottled- gas appliances, and have
threaded compression connections throughout.
PUSH-ON CONNECTIONS MUSTNOT BE USED
(We do not recommend the use of rubber type
flexible tubing for connecting permanently operating
appliances of this type in the United Kingdom). All
connectors etc. should be of a type specifically desi
11