Dometic RM 6261(L) Refrigerator User Manual


 
21
Installation recess
The refrigerator must be installed draught-free in a recess.
The measurements of the recess are given in the table below.
Step (A) is only required for cabinets with a step. Push the appliance far enough into
the recess until the front edge of the refrigerator casing is flush with the front of the
recess. Allow a gap of 15-20 mm between the back wall of the recess and the
refrigeration unit. The floor of the recess must be level, allowing the appliance to be
pushed easily into its correct position. The floor must be substantial enough to bear the
weight of the appliance.
Ensure that the refrigerator is installed level in the recess.
Recess measurements:
Model Hight H Width W Depth T Hight HSt Depth TSt
RM 6270 825 mm 490 mm 515 mm 220 mm 235 mm
RM 6271 825 mm 490 mm 515 mm 220 mm 235 mm
RM 6290 825 mm 529 mm 515 mm 220 mm 235 mm
RM 6291 825 mm 529 mm 515mm 220 mm 235 mm
RM 6360 825 mm 490 mm 515 mm - -
RM 6361 825 mm 490 mm 515 mm - -
RM 6400 825 mm 529 mm 515 mm - -
RM 6401 825 mm 529 mm 515 mm - -
RM 7270 825 mm 490 mm 515 mm 220 mm 235 mm
RM 7290 825 mm 529 mm 515 mm 220 mm 235 mm
RM 7360 825 mm 490 mm 515 mm - -
RM 7400 825 mm 529 mm 515 mm - -
Securing the refrigerator
In the sidewalls of the refrigerator, there are four plastic
sleeves with screws for securing the refrigerator. The
sidewalls or rails attached for securing the refrigerator
must be designed in such a way that the screws will
remain firmly in place even when under increased load
(while the vehicle is moving).
Always insert screws through the sleeves provided;
otherwise, structural parts embedded in the foam,
such as cables, etc., may be damaged.
Once the refrigerator is in its final position, secure the
screws into the wall of the recess.
The screws must penetrate through the sheet metal
casing of the refrigerator.
6.5
Width of recess = W
Width of recess = W
6.6