Earlex VAP75 Ventilation Hood User Manual


 
STRIPPING: Remember to check a small area first.
Operation is simple for both right and left handed people.
Simply hold the steam plate flat against the wallpaper for approx. 10 seconds. Now move the plate
to the spot immediately next to the one just steamed - from which the paper should now easily
come away with a little help from a wall scraper
.
Working this way should enable continuous paper removal although it may be necessary to steam
for longer periods with some papers, or if not completely removed first time.
Operate steamer until water level is low, then unplug unit and allow to cool for at least 2 minutes
before removing filler cap - Beware of steam - and re-filling unit.
When finished, allow to cool completely and empty unit. Always store unit empty.
SAFETY CUT-OUT
A safety cut-out is fitted to prevent overheating the element if the water boils low. If unit stops boiling during use this
may be the cause. Wait for 2 minutes before removing filler cap then re-fill with water. The cut-out will self reset and
steam be produced again within 5-15 minutes.
The cut-out will not protect the element if a part filled unit is tilted during use in a way which enables part of the
element to be out of the water for longer than 15-20 seconds.
OTHER USES FOR THE STEAM PLATE
Artex
Normally Artex can be removed using the same method as for wallpaper although the steaming time will be longer.
CAUTION: Some textured finishes may contain asbestos which may be hazardous to health and which are subject to
licensing controls operated by the HSE (Health & Safety Executive).
V
inyl Floor Tiles
Vinyl floor tiles can also be removed if the plate is left long enough for the heat to penetrate the adhesive. Once the
adhesive is hot it softens and the tile can be peeled from the floor.
Sterilising Soil
To sterilise soil in seed trays or greenhouses rake the soil to obtain a fine surface. Leave the
steam plate on each section, for 2 to 2.5 minutes which should ensure that the steam has
penetrated through the surface.
Killing Weeds
Steam will kill weeds on paths and patios without the use of chemicals. You will need to steam
the weeds for 1 to 1.5 minutes in order to kill them.
TROUBLE SHOOTING
Unit Fails to Boil
The unit has probably not been left for long enough to cool- refer to section on safety cut-out. Check the fuse in the plug
is sound and is rated at 13 amps.
If using an extension lead check that it is rated at a minimum of 10 amps and fully unwound.
Unit Leaks Steam from Pressure Relief Valve
The pressure relief valve is a special low pressure valve and cannot be replaced by any other valve. If steam is leaking
from the valve, the most likely cause is a blockage in the hose. Allow the hose to cool then remove the hose and check
for any blockage. Always check the inlet in the tool you are using.
UNDER NO CIRCUMSTANCES FORCE THE VALVE SHUT. THIS IS OPERATING FOR YOUR PROTECTION.
DESCALING
To maintain peak performance of the unit, particularly in areas of hard water, it may be necessary to descale the
element in the unit. Proprietary kettle descaling products can be used in your unit - always follow the manufacturer’s
instructions.
IF YOU REQUIRE FURTHER
ASSISTANCE PLEASE CONTACT OUR HELPLINE ON:
Tel: 01483 454666 Fax: 01483 454548 email:enquiries@earlex.co.uk
Opening Hours: Monday-Friday 08.30-18.00 (excluding Bank Holidays)