ELAN Home Systems U102110-07 Cooktop User Manual


 
SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
32
Conversion to LP gas
Check in the Technical Data
section at the back of the book
that the cooker is convertible to
the gas you want to use.
This conversion must be performed by a
competent person. After conversion the
installation must comply with the relevant
regulations and also the local electricity supply
company requirements. Read the instructions
before converting this appliance.
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and
lead to prosecution.
This instruction must be used in conjunction with the
rest of the appliance instruction, in particular for
information on Standards, cooker positioning,
connection hose suitability etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas
controls.
Jets
Standard burner Wok burner
A jet, B internal injector, C external injector
Remove burner caps and heads. Remove old jets. Fit
new jets (see Technical Data section at the back of the
book for correct jets). Reassemble in reverse order.
Tap adjustment
Pull off all the control knobs. If the hand rail has been
fitted remove it - remove the plastic blanking plugs and
remove the 2 end bracket fixing screws.
Remove the 2 cross headed screws that were hidden
by the hand rail end brackets.
Open the oven door & or grill door and remove the
fixing screws underneath the control panel. NB some
models have a plate under the facia held in place by
the bottom fixing screws.
Lower facia panel clear of top retaining tags.
A tap bypass screw
Turn the bypass screw on each gas control clockwise
to the stop.
Stick on label
Stick the appropriate label on to the data badge to
indicate the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the left
hand hotplate burner jets. Lift off a burner head. Fit the
pressure gauge to the jet. Turn on the hotplate burner
and turn on and light one of the other burners.
Reassemble burner top, making sure it is reassembled
in the correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.