Electrolux 15 Refrigerator User Manual


 
19
Maintenance / Storage, Vacation and Moving
Inlet Screen Cleaning —
Every Year
The solenoid valve inlet screen must be cleaned at
least once each year as follows:
1 Shut off the water at the water supply valve.
2 Pull the unit out to access the back panel.
3 Disconnect electrical power to the unit.
4 Disconnect the entire hose connector from
the water solenoid valve (see Figure 33).
5 Use a tooth brush to clean sediment from the
inlet screen. DO NOT remove the screen.
6 Re-connect the water supply line to the water
solenoid valve. Tighten connector securely.
Open the water supply valve and check for
leakage at the water connection. Make sure
the water supply line is not kinked.
7 Reconnect power to the unit before re-
installing.
8 Make sure the drain system is working
properly and the drain hose is not pinched or
kinked. Pour one gallon of cool, fresh water
into the ice bin. The water should drain freely.
If your ice maker is equipped with a drain
pump, the pump should drain the ice bin.
UL103_CO
WATER
CONNECTION
Figure 33
Draining for non-use
If the unit is to be stored, moved or not used for
extended periods, it will be necessary to drain the
system of water.
CAUTION
If the ambient temperature is expected to
drop below 45°F (7°C), drain all water from the
unit to prevent freezing damage, which is not
covered by the warranty.
IMPORTANT
It is possible that dirt or scale will dislodge in the
water line. Always throw away all ice cubes made
during the first 24 hours of operation when the
unit is returned to service.
NOTE
Back panel must be removed prior to
disconnecting the water lines.
WARNING
Electrical Shock Hazard. Disconnect power
before servicing. Before operating replace all
panels. Failure to do so can result in death or
electrical shock.
1 Disconnect power from the unit.
2 Remove ice from the storage bin.
3 Shut off water supply at the main water
source.
4 Disconnect the inlet and outlet lines to the
water valve and allow them to drain.
IMPORTANT
The use of antifreeze or other products of this
nature is not necessary and is not recommended.
5 Reconnect inlet and outlet lines to the water
valve.
6 Replace back panel.
7 Drain water from the water trough and drain
line by removing the overflow tube (see
Figure 32).
8 Clean the ice maker and storage bin before
next use.
9 Prop door open to allow for air circulation and
prevent mold and mildew.