Clearances and Dimensions
1. Location—Check location where the range will be
installed. Check for proper electrical and gas supply,
and the stability of the floor.
2. Dimensions that are shown must be used. Given
dimensions provide minimum clearance. Contact
surface must be solid and level.
Provide Proper Fuel Type
Before Proceeding: Your appliance was preset at the factory
to operate on Natural Gas only.
DO NOT attempt to convert this range to L.P.
(Propane) Gas. This appliance is designed to operate with
Natural Gas only.
Español - Páginas 9-16
If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
44 5/8"
46
Door Open
5/8"
30"
13"
18"
SIDE
VIEW
Minimum to
Cabinets on
Either Side
of Range.
0" Clearance Below CookingTop and at Rear of Range.
Maximum Depth
for Cabinets
Above Range Top.
36"
30"
25"
FRONT
VIEW
25
3/4"
30"
Minimum
*Minimum to
Side Wall
on Either
Side of
Range 5"
OVERALL
DIMENSIONS
*5"
24"
30"
36"
(Adjustable)
48
1/2”
29
7/8"
(Maximum)
Note: For appliances installed in the
Commonwealth of Massachusetts please be
sure to read page 2.
Refer to your serial plate for
applicable agency certification
30"
p/n 316469102 Rev B (0812)
Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each
1000 ft. above sea level.
1
INSTALLATION INSTRUCTIONS FOR FREESTANDING GAS RANGE