Electrolux 318201432 Cooktop User Manual


 
2
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Figure 2 – COUNTERTOP CUTOUT OPENING
CAUTION
To eliminate the risk of
burns or fire by reaching over heated
surfaces,cabinetstoragespacelocated
above the cooktop should be avoided. If
cabinetstorageisprovided,riskcanbe
reduced by installing a range hood that
projectshorizontallyaminimumof5"
(12.7 cm) beyond the bottom of the
cabinets.
Letters on this figure refer to chart on front page except for J, K & L.
Overhead Cabinet Should Not Exceed a
MaximumDepthof13"(33cm)
30"(76.2cm)Min.
Clearance Between the
Top of the Cooking
Platform and the Bottom
of an Unprotected Wood
orMetalCabinet.
24"(61cm)Min.when
BottomofWoodorMetal
Cabinet is Protected by
Not Less Than 1/8" (0.3
cm) Flame Retardant
MillboardCoveredWith
Not Less Than No. 28
MGSSheetSteel,0.015"
(0.4 mm) Stainless
Steel,0.024"(0.6mm)
Aluminum or 0.020" (0.5
mm) Copper.
21/2"(6.4cm)Min.FromEdge
of Cutout to Front Edge of
Countertop
Approximate Location
of Junction Box
18"
(45.7 cm)
J Min.FromEdgeof
Cooktop to Nearest
Combustible Wall
(Either Side of Unit).
12"
(30.5 cm)
10"
( 25.4 cm)
KMin.Recommended
Distance Between Rear
Edge of Cutout and
Nearest Combustible
Surface Above
Countertop
24"
(61 cm)
Min.
L
If a drawer is present
underneath,allowatleast
6½" (16.5 cm) of clearance
below the countertop.
CAUTION
Never store
flammable products in the
drawer.
MODEL J K L
30’’ (76.2 cm) 7½’’ (19.1 cm) 2’’ (5.1 cm) 30’’ (72.6 cm)
36’’ (91.4 cm)
7½’’ (19.1 cm). 2’’ (5.1 cm) 36’’ (91.4 cm)