BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 2.9 0.65 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.276 0.062 0.181 0.043 0.095 0.031
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
1/100 mm
NOMINAL THERMAL
POWER kW 2.7 0.65 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 195 46.8 137 32.4 72 23.8
NOZZLE REFERENCE 86 40 71 32 50 28
1/100 mm
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and
Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current
Edition).
Detailed recommendations are contained in the following British Standards
Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current
Editions.
The hob should not be installed in a bed sitting room with a volume of less
than 20 m
3
. If it is installed in a room of volume less than 5 m
3
an air vent of
effective area of 110 cm
2
is required. If it is installed in a room of volume
between 5 m
3
and 10 m
3
an air vent of effective area of 50 cm
2
is required,
while if the volume exceeds 11 m
3
no air is required.
However, if the room has a door which opens directly to the outside no air vent
is required even if the volume is between 5 m
3
and 11 m
3
.
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2
Current Edition, should be consulted to determine the requisite air vent
requirements.