A. EARTH CONTINUITY CHECK
Appliance must be electrically disconnected - meter set on (Ohms) x 1 scale and
adjust zero if necessary.
Test leads from any appliance earth point to earth pin on plug. Resistance should
be less than 0.1 (Ohm), check all earth wires for continuity and all contacts
are clean and tight.
B. INSULATION CHECK
Appliance electrically disconnected, all switches ON.
a) meter set on (Ohms) x 1 scale.
Test leads from L to N in appliance terminal block. If meter reads «0» then there
is a short circuit.
b) meter set on (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads less than (infinity) there is a
fault.
NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed
continuity check (i.e. by disconnecting and checking each component) is required to trace
the faulty component.
It is possible that a fault could occur as a result of local burning/arcing but no fault could be
found under test. However a detailed visual inspection should reveal evidence of burning
around the fault.