Electrolux 9CHG584102 Fryer User Manual


 
INSTALLATION INSTRUCTIONS
62.9679.01_UL Seite 5
II . INSTALLATION INSTRUCTIONS
1. INSTALLATION
The appliance is designed for connection to fixed lines. The
appliances are suitable for setting up as single appliances or as
a group of appliances. They can be set up freely in the room,
side by side, at the side and/or at the back against a wall.
Gaps between two appliances or appliance and sidewall
should be filled with a FDA approved silicone such as Samco
RTV103.
1.1 DISTANCES
If an appliance is set up next to or against temperature-sensi-
tive furniture or similar, a safety gap of approximately 6“ (150
mm) should be maintained or some form of heat insulation fit-
ted.
The walls must be made up of non-combustible material like
tiles or steel.
1.2 HEIGHT ADJUSTMENT
Appliance on feet.
D Turn the lower part of the feed to adjust the appliance high.
The feet are adjustable from 4“ to 8“ (100 to 200 mm). A high
of 8“ (200 mm) can be recommended and results in an appli-
ance high of 35,4“ (900 mm).
Note:
Adjustment of the legs shall provide an unobstructed
clearance of minimal 6“ (150 mm) and maximal 8“ (200
mm) beneath the unit due to sanitary and stability
aspects.
The lower part of the foot must not be unscrewed too far.
The exposure of threads is prohibited.
1.3 ASSEMBLING TWO APPLIANCES
The assembly kit contains two of each of the following:
caged nuts (1 / Fig.1) pre-assembled on the right-hand side of
the appliance, hexagonal screws M8x25 (1 / Fig.1) and moun-
ting links (2 / Fig.1)
D Remove the control panels from both appliances as in 2.2
D Remove the front panels from both appliances as in 2.1
D Keeping the screw (1 / Fig.1) loose, turn it until it is approxi-
mately 5 mm deep in the caged nut.
Positioning the appliances:
D Place the appliances next to one other.
D Align for position and height.
Connect the appliances:
D Fit the mounting link (2 / Fig.1) into the inside of the second
appliance's left connecting plate.
D Tighten the screws.
Note
If required, the caged nuts can also be fitted on the other side
of the appliance.
Appliance on feet: Alignment is carried out by screwing the
lower foot parts in or out.
Appliance on
steel plinth:
Irregularities or differences in height can
be equalized by inserting one or several
strips of chrome nickel steel.
a
b
c
Fig.1 Lateral connection
(1)
(1)
(2)
(2)
(3b)
(3a)
(3c)
(1)
(2)
1
(3c)