23
LEVELLING FEET
PENCIL LINE ON THE FLOOR
PLAW VIEW OF THE COOKER
480 mm.
100 mm.
300 mm.
295 mm.
WALL FACE
A
BACK OF COOKER
SIDE VIEW
OF THE COOKER
BASE OF COOKER
ENGAGEMENT EDGE FOR
STABILITY BRACKET
Fig. 3
Fitting the Stability Bracket
(Not supplied)
If the cooker has to be installed with a flexible
supply pipe, it is necessary that a stability device is
fitted.
(See safety Requirements: Page 21).
If a stability bracket is to be fitted by the installer,
these instructions should be read in conjunction with
the leaflet packed with the stability bracket.
Place cooker in its intended position and level
cooker.
Mark off 295mm (11
1
/
2
") from the right hand side of
the cooker as shown, this is the centre line of the
bracket fixing.
Draw a line 100mm (4") from the front edge of the
levelling feet (see Fig. 2) and remove cooker from its
position. Mark off 480mm (19") back from this line
on the centre line of the bracket to locate the front
edge of the lower bracket.
Fix lower bracket (with two fixing holes) to the floor,
then measure height from floor level to engagement
edge on back of cooker, dimension 'A' of Fig. 2.
Assemble upper bracket to lower bracket so that
underside of bracket is dimension 'A' +3mm (1/8")
above floor level. Re-position cooker and check that
top bracket engages into cooker back to a depth of
75mm (3"), as shown in Fig. 2.
Should the stability bracket currently installed not
allow the cooker to stand correctly, ask the installer
to replace it with the correct type.
Fig. 2
Connecting to Gas
This cooker is designed to be installed with an
appliance flexible connection. Connection is made to
the RC 1/2 (1/2" B.S.P.) threaded entry pipe located
just below the hotplate level on the rear right-hand
side of the cooker. Check for gas soundness after
connecting the gas supply.
The gas bayonet connector must be fitted in the
shaded area indicated in the diagram. Take into
account that it must be possible to pull the cooker
forward sufficiently. The hose must not get caught on
the stability bracket.
Note:
For certain types of gas bayonet connection used, it
may not be possible for the appliance to be pushed
fully back to the wall stops.
Important:
Flexible tubing MUST comply with BS.669 Current
Edition.
FO 0179
FO 2435
600
450
130