Microwave Oven/Electric Single Wall Oven/Warmer Drawer
Combination Installation Specifications
Always consult local and/or national electric codes.
(Refer to product-specific electrical specifications on this page.)
Minimum 24"deep cutout dimension is critical for proper combination
installation, to ensure that each built-in product’s faceplate will fit
flush against cabinet front.
Bases must be level and cabinet front must be square.
Minimum 4-1/2"required distance from bottom of Warmer Drawer
cutout to floor.
Respect critical dimensions as noted for proper installation of built-In
products.
Minimum 23-1/4" clearance needed for Wall Oven door depth
when open.
30" Built-In Convection Microwave Specifications
Product Weight – 60 Lbs.
Voltage Rating –120V/ 60Hz/15 Amps
Connected Load (kW Rating) @120 Volts =1.55kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @120 Volts =13 Amps
Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
Minimum 3-1/8"clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2"visible area
between both product faceplates.
30" Electric Single Wall Ovens Specifications
Product Weights – (E30EW75GPS) 178 Lbs. / (E30EW75GSS) 175 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
Connected Load (kW Rating) @ 240/208 Volts = 4.0/3.0kW
Amps @ 240/208 Volts =16.6/14.4 Amps
To support Wall Oven, two 3"-wide x 3/4" thick planks must be installed
as a base, capable of supporting 200 Lbs. Do NOT use full base, since
planks are necessary to allow for proper air displacement.
30" Warmer Drawers Specifications
Product Weights – (E30WD75GPS/E30WD75GSS) 49 Lbs. /
(E30WD75GTT) 41 Lbs.
Voltage Rating –120V/450W/60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 0.45kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @120V = 3.75 Amps
Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
Note: Refer to Product Installation Guide for detailed instructions
on the web at electroluxusa.com.
24"min.
3"max.
††
30"min.
9
7
/8"min.
10
1
/4"max.
1
3
/4"min.
26
1
/2"min.
27"max.
E30EW75GPS
E30EW75GSS
Electric Single
Wall Oven Cutout
Full plywood base
required to support
100 lbs.
Full plywood base
required to support
100 lbs.
28
1
/2"min.
28
7
/8"max.
28
1
/2"min.
29"max.
E30MO65GSS
Microwave Oven
Cutout
Two 3" wide
by
3
/4" thick
planks must be
installed, capable
of supporting
200 lbs.
E30WD75GPS
E30WD75GSS
E30WD75GTT
Warmer Drawer
Cutout
4"x 4" opening to route
armoured cable
28
1
/2"min.
29"max.
5"
11
1
/2"
120V/60Hz
grounded electrical
outlet should NOT
be located within
shaded area
4
1
/2"min.
required
19
7
/8"min.
20
3
/8"max.
24"min.**
(critical
dimension)
Electrical junction
box location
Bottom of
oven cutout
11
5
/8"min.**
(critical
dimension)
2"
(visible
area)*
For detailed product dimensions
and installation specifications, refer
to model-specific product sheet and
installation instructions on web
* Minimum 3
1
/8"
clearance required
from bottom of
Built-In Microwave
Oven cutout to top
edge of Wall Oven’s
faceplate, leaving
a 2"visible area
between both product
faceplates
** Critical dimension –
MUST be applied
Maximum height
depends on critical
dimension (11
5
/8")
††
Electrical junction
box for Wall Oven
must be lower than
the Warmer Drawer
cutout