Electrolux E36GC75GSS Cooktop User Manual


 
Slide-In Cooktop/Downdraft Vent
Countertop Preparation Specifications
For detailed Slide-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
Position cooktop/vent cutout so all required minimum clearances
are met.
Minimum flat countertop area must meet or exceed combined overall
width and depth as shown.
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
Always consult local and/or national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
Proper combination installation will require 30" & 36" Gas Slide-In
Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Downdraft Vent Specifications
For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
Voltage Rating –120V/ 60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
Amps @120 Volts = 8.0 Amps
Vent unit outside of building only.
Vent must be installed in vertical orientation only.
1,600 CFM remote exhaust blower (part number 5304444802) included
with vent – shipped in separate box.
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.
Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Cold weather installations should have additional backdraft damper
installed.
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
SIC_DDV_PREP 05/08 © 2008 Electrolux Home Products, Inc. Printed in the U.S.A.
Countertop Preparation for 30" & 36" Slide-In Cooktop/Downdraft Vent Installation
For detailed cooktop and downdraft vent
installation specifications, refer to model-specific
product page and installation guide on web
7
1
/4"
Opening for
downdraft vent
B
A
1"countertop
overhang
C
2
13
/16"
7
1
/2"
E
D
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops A B C D E
E36EC75DSS 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36EC75ESS 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36EC75HSS 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36GC75DSS* 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36GC75ESS* 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36GC75GSS* 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36GC76EPS* 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E36GC76GPS* 35
15
/16" 35
3
/16" 22" 25
13
/16" 33
3
/4"
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktop A B C D E
E30GC74GPS* 29
15
/16" 29
3
/16" 22" 25
13
/16" 27
1
/2"
*Proper combination installation will require cooktop power cord
to be relocated to underside of unit.
(For details, refer to 30" & 36"
Gas Slide-In Cooktop Power Cord Relocation Instructions page.)
Slide-In Cooktop / Downdraft Vent
Countertop Preparation