Electrolux E36GC76EPS Cooktop User Manual


 
19
Operation
Turn on the main gas supply to the cooktop by opening the gas shut-off valve. Test
each burner separately by pressing and turning one control knob at a time
counterclockwise to the “LITE/HI” position. All ignitors will spark simultaneously. (It
will take approximately four seconds for ignition to occur, at which time all igniters
will stop sparking. If ignition does not occur within four seconds, turn off the knob,
wait for at least five (5) minutes to allow any gas to dissipate, then repeat this
ignition test.) The control knob can then be rotated counterclockwise from “HI” to
“LOW” to adjust the flame height progressively. Repeat the ignition test for all
burners.
When installed properly, the flame will be steady and quiet. It will also have a sharp,
blue inner cone that will vary in length proportional to the burner size. Flame
adjustment will not be necessary.
Read and understand the accompanying Use & Care Manual prior to cooking with
this appliance. The Use & Care Manual contains additional important safety,
service and warranty information.