Electrolux E36GF75GPS Range User Manual


 
22
IMPORIMPOR
IMPORIMPOR
IMPOR
TT
TT
T
ANTANT
ANTANT
ANT
After replacing the natural gas to LP orifices, be sure to keep the original factory
installed natural gas orifices for future range conversion back to natural gas. The
factory orifices are marked with the following: Top Burners 165; Oven Burner 226; Oven
Broiler 185; Griddle 206; Main Burner Bypass Jet; Simmer Bypass Jet
*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced
at a rate of 4 percent for each 1000 ft. above sea level
Determine the combination of top burners that are featured on your range.
Identify the parts you need from this kit to complete the L.P. conversion. When
burners are converted from natural to L.P. the BTU ratings are as follows:
Top burner 15,000 BTU L.P. Gas
Oven Burner 22,000 BTU L.P. Gas
Oven Broiler 16,500 BTU L.P. Gas
Griddle 18,500 BTU L.P. Gas
INSTRUCTIONS FOR CONVERTING RANGE FROM
NATURAL GAS TO LP GAS
Conversion To LP Gas
Quantity Part Description Notes
1 LP Conversion kit label
1 Instruction for converting range to LP Gas
1 LP Conversion Label
6 Orifice - Top Burner, #58
6 Orifice - Simmer Burner, .46mm
1 Orifice - Oven Burner, #55
1 Orifice - Oven Broiler, #56
1 Orifice - Griddle, #55
6 Main burner bypass jet, blue ring
6 Simmer burner bypass jet