18
Operation
VERIFYING THE OPERATION
Before beginning the test procedure, ensure that the gas supply is turned off at the
shut-off valve, all cooktop control valves are in the “OFF” position, and all burner
rings, burner caps, and grates are properly positioned on the cooktop.
Rotate one knob at a time counterclockwise to the “LITE/HI” position. Verify that all
ignitors spark continuously, then return the knob to the “OFF” position. Repeat for
all knobs. See Figure 8.
WARNINGWARNING
WARNINGWARNING
WARNING
•If the cooktop fails to operate properly, ensure that the electrical power supply
and gas supply are turned on and that all installation steps have been carefully
followed. Call a qualified service technician if the cooktop still does not operate
properly.
•The cooktop and shut-off valve must be disconnected from the gas supply piping
during any pressure testing exceeding 1/2 pound per square inch (3.5 kPA).
•The cooktop must be isolated from the gas supply piping by closing the shut-off
valve during any pressure testing at or below 1/2 pound per square inch (3.5 kPA).
Figure 8
Burner Control Valve