Electrolux ECM2771 Freezer User Manual


 
Temperature alarm
If the temperature in the freezer
becomes too high, the acoustic alarm
The acoustic alarm signal fails to sound
and the red alarm indicator fails to light
up:
if the power supply to the equipment
fails
in the case that the electronic temper-
ature controller has failed.
Prior to putting into service
Clean the inside of equipment and all the appli-
ances prior to putting into service the first time
(see chapter: "Maintenance")
Adjusting the temperature
setting
Use a coin to turn the temperature control
knob. This is to render it more difficult to
change the setting inadvertently (protection
against children`being able to tamper with
the equipment).
Position "Off" means that the equip-
ment is switched off.
How to use
10 electrolux cold
on putting the equipment into service
until the temperature necessary for
safe food storage is maintained.
after loading fresh food in a quantity
exceeding the freezing capacity (see
"Freezing")
if the lid remains open for long time.
If there is a malfunction and the internal
temperature cannot be maintained.
Green and Yellow: Earth
Blue: Neutral
Brown: Live
The wire coloured green and yellow must
be connected to the terminal marked
with the letter "E" or by the earth symbol
or coloured green and yellow.
The wire coloured blue must be connect-
ed to the terminal "N" or coloured black.
The wire coloured brown must be con-
nected to the terminal marked "L" or
coloured red.
Upon completion there must be no cut,
or stray strands of wire present and the
cord clamp must be secure over the
outer sheath.
sounds and the alarm signal lamp
flashes.
The acoustic alarm signal sound and the
red alarm signal lights up:
Press the button to stop the acoustic
alarm signal. The red alarm lamp
continues to flash until the freezer
reaches the proper temperature.
Signal lamp of the control section
(green).
Signal lamp (yellow) for quick freezing.
Acoustic alarm and alarm signal lamp
(red).
Push button:
- for reset acoustic alarm
- for start quick freezing mode
- for stop quick freezing mode
1.
2.
3.
4.
Description of equipment
Control panel: