Electrolux EFC 650-950-600-900 Ventilation Hood User Manual


 
45
S
9S
2
1
6
6
4
7
5
8
12
13
13
14
15
15
4
4
11
9S
9S
9K
9K
9K
9K
4
Ø 120mm
10S
14
7
K
9K
9K
6
6
7
7
3
3
Wall unit mounting - Fig. 6
Put the template onto the wall (1) and drill two Ø12mm holes (2).
Fit two hooks (3) on the drilled holes.
Remove the metal filters (4) and hang the hood on the hooks and adjust the position of the hood using the two
screws on the bottom of the hooks (5).
Depending on the model, mark 2 or 4 points (6). Remove the hood and drill 2 or 4 Ø8mm holes on the marked
points. Fit 2 or 4 Ø8mm wall dowels, Hang again the hood and fix the hood permanently with 2 or 4 screws
5X45 (7).
Fix the chimney support (8) with two screws 5 x 45 mm and two wall dowels on the wall close to the ceiling.
For the extraction version: Fit the connection ring (S) on the top of the hood with two screws Ø 3,5 x 6,5
mm (9S) then fit a vent hose long enough to reach the outside (10S).
For the recirculation version: Fix definitively the deflector (K) on the top of the hood with two screws Ø
3,5 x 6,5 mm (9K).
Prepare the electric connection (11) (see relative chapter).
Fit the chimney (12) and fix it on the chimney support with two screws 3 x 9 mm (13).
The lower part of the chimney must be slid down and inserted on the housing on the upper part of the hood
(14).
Fit the two grids (15) on both sides
of the chimney.
Fig. 6