Mark the wall with a centre line, this
will aid mounting procedure
(1)(1)
(1)(1)
(1),
position the template so that the mid
line printed on the template matches
with the centre line previously
marked, the lower side of the
template corresponds to the lower
side of the hood once mounted
(2)(2)
(2)(2)
(2).
Drill two holes Ø 8mm and fix the
support bracket with two wall plugs
and screws
(3)(3)
(3)(3)
(3).
Remove the front panels (see
paragraph “Removing the front
panels”) and the grease filter.
Hang the hood
(4)(4)
(4)(4)
(4) adjust its position
(5-6) (5-6)
(5-6) (5-6)
(5-6) and from the inside of the hood
sign two points for definitive fixing
(7)(7)
(7)(7)
(7),
remove the hood and drill two holes
Ø 8mm
(8)(8)
(8)(8)
(8), fit two wall plugs, hang
the hood again and fix it securely
with two screws
(9)(9)
(9)(9)
(9). Cover the drill
holes for screws with the two screw
caps provided.
Make electrical connection
(10)(10)
(10)(10)
(10), but
leave the hood disconnected from
the home mains circuit.
In the case that it is decided to use
the cooker hood in the mains circuit,
then place one of the two flanges
provided in the exit hole (
11 11
11 11
11 –
Extraction). Attention! The tall flange
should be used when a telescopic
chimney is required to be mounted
(this item should be ordered – see
special accessories), the short flange
is to be used in all other cases.
Remount the grease filter and the
front panels (
12a-b-c12a-b-c
12a-b-c12a-b-c
12a-b-c).
11
11
10
12a
12b
12c
Extraction mode
Recirculation mode
1
2
3
4
4
5
6
6
7
8
8
9
(5x18)
(5x18)