45
b
a
Fig. 7
l Dismount the chimney support from the chim-
ney unscrewing the two side screws (one per
side of the chimney- conserve them). (Fig. 7)
l Dismount the deflector "b" from the chimney
support unscrewing the two screws that fix the
deflector to the chimney support (conserve the
screws). (Fig. 7)
l Fit the chimney support onto the wall close to
the ceiling.
The support has a reference mark, this must
match the line previously drawn on the wall.
(Fig. 7)
l Mark with a pencil the hole to be done and drill
the holes (Ø 8mm).
l Insert two wall dowels and fix the telescopic
chimney support with two screws 5x45. (Fig. 7)
The power plug must be disconnected
from the mains during the mounting
procedure.
Make the choice of how to use the hood:
Exhausting version
l Fit a Ø 150 mm exhausting pipe or flex tube on
the hood outlet on top of the motor housing and
connect it to the wall or roof outlet pipe.
Recirculating version
l If not already fitted, fit the connection ring (a -
Fig. 7) supplied (bajonett attachment - turn
clockwise and fix with a screw) on the deflector b.
l Insert the deflector in the chimney support and
fix it with two screws (Fig. 7).
l Fit a Ø 150 mm exhausting pipe on the motor
outlet connection ring sufficiently long to reach
the connection ring on the deflector.
For both versions:
l Now connect the power plug to the wall outlet.
l If a no return valve is used check that it can
open correctly and is not blocked by the flex
tube
l Fix the chimney top part on its support with two
screws (Fig. 7).
l Slide the lower section of the chimney down-
wards and insert it on its proper housing on the
upper side of the hood (Fig. 7).
Mounting of carbon filter (for
recirculating version)
l Remove the grease filter.
l Fix the carbon filter with its two screws (Fig. 8).
l Replace the grease filter.
Fig. 8