Installation
Wall unit mounting - Fig. 7
Disconnect the hood during electrical connection, by turning the home mains switch off.
Remove the 2 screws fitted inside the lower part of the hood at the points in which it is
fixed to the motor unit (see also operation 3).
Rest the motor unit on a flat
surface and thread the lower part
of the chimney section onto it (1).
Make all the electrical
connections between the two
parts (2).
Secure the two parts using 8
screws (3).
Mark the wall with a centre line, this
will aid the fixing procedure (4), position
the template so that the mid line printed on
the template matches with the centre line
previously marked, the lower side of the
template corresponds to the lower side of
the hood once installed (5).
Drill two holes Ø 8mm and fix the support
bracket with two wall plugs and screws
(6).
Hang the hood (7) adjust its position (8-9)
and from the inside of the hood mark one
point for final fixing (10), remove the hood
(11) and drill an hole Ø 8mm (12), fit a
wall plugs (13).
Drill two holes Ø 8mm on the upper side
close to the ceilling (14), fit two wall
plugs and fix the chimney support
with two screws (15).
Hang the hood again (16).
Fix it securely with a screw
(17). To simplify the
installation operation
remove the charcoal filter
frame.
If the hood is used in the
recirculation function, fix
the deflector F on the
chimney support G with 2
screws and fit an extraction
pipe (18 - not supplied) to connect deflector to the outlet hole D of the hood.
In case the hood is to be used in exhausting version, then the deflector must not be
mounted and fit an extraction pipe (18) to connect outlet hole D of the hood to the
outside.
Make the electrical connection (19), but leave the hood disconnected from the
household mains supply.
Fix the chimney (20a) to the chimney support (20b).
Slide down the lower section on the proper housing on top of the hood. Connect the hood
to the household mains supply and check that the hood works correctly.
Fig. 7