Electrolux EHP6602K Cooktop User Manual


 
18
1 Safety Instructions for the Installer
A device must be provided in the electrical installation which allows the
appliance to be disconnected from the mains at all poles with a contact
opening width of at least 3 mm
Suitable isolation devices include line protecting cut-outs, fuses (screw
type fuses are to be removed from the holder), earth leakage trips and
contactors.
In respect of fire protection, this appliance corresponds to type Y (EN 60
335-2-6). Only this type of appliance may be installed with a high cup-
board or wall on one side.
Drawers may not be fitted underneath the hob.
The installation must guarantee shock protection.
The kitchen unit in which the appliance is fitted must satisfy the stability
requirements of DIN 68930.
For protection against moisture, all cut surfaces are to be sealed with a
suitable sealant.
On tiled work surfaces, the joints in the area where the hob sits must be
completely filled with grout.
Ensure that the seal is correctly seated against the work surface without
any gaps. Additional silicon sealant must not be applied; this would make
removal more difficult when servicing.
The hob must be pressed out from below when removed.