Electrolux EHS 60020 K Cooktop User Manual


 
20 electrolux installation instructions
Installation Instructions
Safety instructions
The laws, ordinances, directives and
standards in force in the country of use
are to be followed (safety regulations,
proper recycling in accordance with the
regulations, etc.)
Installation may only be carried out by a
qualified electrician.
The minimum distances to other appli-
ances and units are to be observed.
Anti-shock protection must be provided
by the installation, for example drawers
may only be installed with a protective
floor directly underneath the appliance.
The cut surfaces of the worktop are to
be protected against moisture using a
suitable sealant.
The sealant seals the appliance to the
work top with no gap.
The sealant seals the appliance to the
work top with no gap.
Do not use silicon sealant between the
appliance and the work top.
Avoid installing the appliance next to
doors and under windows. Otherwise
hot cookware may be knocked off the
rings when doors and windows are
opened.
WARNING!
Risk of injury from electrical cur-
rent.
The electrical mains terminal is live.
Observe connection schematic.
Observe electrical safety rules.
Ensure anti-shock protection
through correct installation by a
qualified electrician.
The appliance must be connected to
the electrical supply by a qualified
electrician.
IMPORTANT!
Risk of injury from electrical cur-
rent.
Loose and inappropriate plug and sock-
et connections can make the terminal
overheat.
Have the clamping joints correctly in-
stalled by a qualified electrician.
Use strain relief clamp on cable.
In the event of single-phase or two-
phase connection, the appropriate
mains cable of type H05BB-F Tmax
90°C (or higher) must be used.
If this appliance’s mains cable is
damaged, it must be replaced by a
special cable (type H05BB-F Tmax
90°C; or higher). Please contact your
local Service Force Center for further
advice.
A device must be provided in the electri-
cal installation which allows the appli-
ance to be disconnected from the mains
at all poles with a contact opening width
of at least 3 mm
Suitable isolation devices include line
protecting cut-outs, fuses (screw type
fuses are to be removed from the hold-
er), earth leakage trips and contactors.